Blisstool LTC48X Guía de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
14.3. Settings for terrains with low degree of mineralization
<TDAVL> Terrain optimized setting in discrimination mode and automatic ground
balance for no contaminated terrains with low degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „AUTO“
AUTO ZONES switch: position „3“ or „2
DISCR LEVEL potentiometer: at LTC48X v2 of level „4“, while at LTC48X v1 of level „7“
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of levels from „6“ to „10“
<TDGVL> Terrain optimized setting in discrimination mode and manual ground
balance for no contaminated terrains with low degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „4“, while at LTC48X v1 of level „7“
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of levels from „6“ to „10“
<TDACL> Terrain optimized setting in discrimination mode and automatic ground
balance for contaminated terrains with low degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „AUTO“
AUTO ZONES switch: position „3“ or „2
DISCR LEVEL potentiometer: at LTC48X v2 of level „5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of levels from „6.5“ to „10“
<TDGCL> Terrain optimized setting in discrimination mode and manual ground
balance for contaminated terrains with low degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: of the zoom level (usually between levels from „4“ to „6“)
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of levels from „6.5“ to „10“
BLISSTOOL LTC48X - User Guide (version EN201008241400) Page 24 of 28
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28

Comentarios a estos manuales

Sin comentarios